Objectives: Report the results of 3 years of Universal Neonatal Hearing Screening (UNHS) at the Neonatal Intensive Care Unit (NICU), CHULC; identify cases of delayed auditory pathway maturation.

Study design: Retrospective observational. 

Methods: UNHS data from NICU newborns, admitted for ≥ 5 days, during 3 years were retrieved and analyzed. NHS results were classified as following: (1) “pass” when both ears for both the a-TEOAE (automated transiente-ecoked otoacoustic emissions) and the a-ABR (autoated auditory brainstem response) protocol resulted as “pass”; (2) “fail” when one ear, at either one of the two performed tests resulted as “fail”; (3) “missing” when the newborns were not tested. 

Results: 75.3% resulted as “pass”, 19.7% “fail” and 5% as “missing”. From “fail group”, 58.7% resulted as “pass”, 25.3% as “fail” and 16% “missing”. Among those, 10.5% 1) wave V identifiable over 30dB nHL; and 2) a bilateral wave V identifiable within 30dB nHL, in a following clinical ABR test. These group were defined to have an delayed auditory pathway maturation. 

Conclusions: A delay of the auditory pathway maturation has been hypothesised in 2 out of 380 (0.53%). 

References

- American Academy of Pediatrics, Joint Committee on Infant Hearing, Year 2007 position statement: principles and guidelines for early hearing detection and intervention programs. Pediatrics. 2007 Oct;120(4):898-921. doi: 10.1542/peds.2007-2333.

- Rastreio e tratamento da Surdez com implantes cocleares em idade pediátrica. Norma 018/2015. 11/12/2015. Direção Geral da Saúde Disponível em https://www.dgs.pt/directrizes-da-dgs/normas-e-circulares-normativas/norma-n-0182015-de-1122015-pdf.aspx.

- Johnson JL, White KR, Widen JE, Gravel JS. et al. A multicenter evaluation of how many infants with permanent hearing loss pass a two-stage otoacoustic emissions/automated auditory brainstem response newborn hearing screening protocol, Pediatrics. 2005 Sep;116(3):663-72. doi: 10.1542/peds.2004-1688.

- Colella-Santos MF, Hein TA, de Souza GL, do Amaral MI. et al. Newborn hearing screening and early diagnostic in the NICU. Biomed Res Int. 2014;2014:845308. doi: 10.1155/2014/845308.

- Bielecki I, Horbulewicz A, Wolan T. Risk factors associated with hearing loss in infants: an analysis of 5282 referred neonates. Int J Pediatr Otorhinolaryngol. 2011 Jul;75(7):925-30. doi: 10.1016/j.ijporl.2011.04.007.

- Cianfrone F, Mammarella F, Ralli M, Evetovic V. et al. Universal newborn hearing screening using A-TEOAE and A-ABR: the experience of a large public hospital. J Neonatal Perinatal Med. 2018;11(1):87-92. doi: 10.3233/NPM-181744.

- J. Eggermont, A. Salamy, Development of ABR parameters in a preterm and a term born population. Ear Hear. 1988 Oct;9(5):283-9. doi: 10.1097/00003446-198810000-00009.

- Pasman JW, Rotteveel JJ, de Graaf R, Maassen B. et al. The effects of early and late preterm birth on brainstem and middle-latency auditory evoked responses in children with normal neurodevelopment. J Clin Neurophysiol. 1996 May;13(3):234-41. doi: 10.1097/00004691-199605000-00007.

- Hof JR, Stokroos RJ, Wix E, Chenault M. et al. Auditory maturation in premature infants: a potential pitfall for early cochlear implantation. Laryngoscope. 2013 Aug;123(8):2013-8. doi: 10.1002/lary.24054.

- Coenraad S, Goedegebure A, Hoeve LJ. An initial over estimation of sensorineural hearing loss in NICU infants after failure on neonatal hearing screening. Int J Pediatr Otorhinolaryngol. 2011 Feb;75(2):159-62. doi: 10.1016/j.ijporl.2010.10.026

Published

2020-10-01

How to Cite

Infante Velada, T., Correia, I., Martins, I., Sousa, H., & Barros, E. (2020). Newborn hearing screening and Auditory Maturation at the CHULC Neonatal Intensive Care Unit. Portuguese Journal of Otorhinolaryngology and Head and Neck Surgery, 58(3), 139–143. https://doi.org/10.34631/sporl.870

Issue

Section

Original Article